24/7 rapid response for Hampshire businesses.
Full BS EN 16005 compliance checks.
Adjusting radar for weather in Hampshire.
Replacing dead UPS packs for safety.
False activations, known as phantom opening, are common in Hampshire due to reflective surfaces. We calibrate Bea Eagle sensors to ignore interference. Crucially, we test the light curtain presence sensors to ensure the door never closes on a pedestrian.
A snapping sound often indicates a worn toothed belt. In Hampshire, we replace these with steel-core timing belts that resist stretching. We also inspect the nylon rollers. Replacing worn rollers eliminates friction, allowing the door to glide effortlessly.
The core of your system in Hampshire is the Brushless DC Motor. When these fail, you might hear grinding noises. We diagnose specific faults like overheating windings and replace the unit with OEM parts to restore factory performance.